Abstract

PMID 9187396

Catheter-Locking Device-Assisted External Ventricular Drain Placement: A New Surgical Technique Preventing Intracranial Drain Displacement-Technical Note with Preliminary Single-Center Results

Abstract


Background External ventricular drain (EVD) placement is frequently performed in neurosurgical patients to divert cerebrospinal fluid (CSF) and monitor intracranial pressure. The traditional practice is the tunneled EVD technique performed in the operating room. EVD insertion through a bolt in intensive care units has also been reported. We describe here the usage of a novel technique, the " catheter-locking device -assisted" EVD placement, reporting our preliminary, observational single-center results. Methods From January to October 2021, 15 patients underwent a "catheter-locking device-assisted" EVD placement at our institute. For each of these patients, the following data were evaluated: (1) demographics, (2) etiology, (3) clinical presentation, (4) EVD complications, and (5) final clinical outcomes. Results Median age of our population was 64 years, with a female/male ratio of 2:1. Average Glasgow Coma Scale score on admission was 8. Each patient maintained the drainage for an average time of 14 days. None of the patients suffered from postoperative intracerebral hemorrhage, CSF leakage, catheter migration, or discontinuation of the drainage system; none developed signs of infection. Nine patients required a permanent CSF diversion system. Outcome was good in 14 patients. One patient died for the underlying disease. Conclusions The "catheter-locking device-assisted" EVD placement appears to be a safe and accurate alternative to both the standard tunneled and the bolt-assisted EVD insertion techniques. The use of this procedure may significantly reduce the incidence of the commonest EVD complications, though further investigation is required.


This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.

OTHER FORMATS

ACTIONS

RESOURSES